FSAK1200F

FSAK1200F


FSAK1200F -1 FSAK1200F -2 FSAK1200F -3

The FSAK1200F power supply is capable of “HOT SWAP” exchanging with active current sharing and OR-ing isolation MOSFETs built in for +12V output, and droop current sharing and OR-ing
isolation diode built in for +5Vsb output. The AC input is rated 90-264Vrms with power factor corrected (PFC > 0.95). A 38mm high reliable Sanyo Denki fan is installed to the power supply module for cooling the power supply module.

The series of power supply also design with the output power range from 750W to 1200W and with +12V & +5Vsb output rails for 1U/2U system application.

Option: Power cord retention kit is available for this power module.

Specifications:

Input

Voltage/Current Label Rating Parameter Min/ Nominal Input/ Max/ Unit
Vin Voltage 90/ 100-240/ 264/ Vrms
Vin Frequency 47/ 50-60/ 63/ Hz
Vin Current 15.0 A
Inrush current The inrush current of power supply module is less than 120A under the conditions of 240Vrms input and 25C ambient cold start.

Outputs

DC Output Voltage +12V Range ±5%
+5Vsb Range ±5%
DC Output Load Distributions +12V, 0.5-100A
+5Vsb, 0-4A
DC Output Efficiency The power supply efficiency is 80% minimum measured at 20%, 50%, full load and nominal line input, which is 115Vrms and 230Vrms conditions.
Over Voltage Protection (OVP) 130% maximum for +12V output. 12VDC: 13.6~15.6V
Over Temperature Protection Internal temperature sensing over 55C will shut down PS. Automatic recovery.
Over Current/Short Circuit Protection Output short circuit is defined as any output impedance of less than 0.1 ohms.

Signals, Indicators, and Controls

DC Power Indicator
  1. Green color – Power module is ON and working properly.
  2. Amber color – Power module is under Standby Mode.
  3. No color – Power module is not working properly.
Audible Alarm & TTL Signal The Audible alarm and TTL signal are available from the signal card located on the backplane
Fan Failed Signal (I2C) The Rotation Detector O/P signal is generated by fan.
Temperature Warning Signal (I2C) The Temperature Warning signal: “0” PS is under normal condition and “1” PS is under full load and over 55oC

Mechanical

Weight 3.5 lbs (1.56 kg)
Dimension 308mm (L) x 79mm (W) x 39.2 (H)

Operating Environment

Temperature Operating +0C to +50C
Non-operating -40C to +85C
Cooling 38mm high reliable fan.
Relative Humidity Operating 10% to 90% relative humidity (non-condensing)
Non-operating 5% to 95% relative humidity (non-condensing)
Altitude Operating 0 to 10,000 feet.
Storage 0 to 50,000 feet
MTBF 100K hours minimum at full load 25oC
Maintenance No routine maintenance is specified or required.

Safety, Regulatory and EMC

RoHS Compliance yes
Emissions power supply can comply with FCC Part 15 and EN55022: 2006 meeting Class B for both conducted and radiated emissions with a 3 dB margin.
Immunity The power supply can comply with EN 55024: 1998+A1: 2001+A2: 2003.
CE EN 55022: 2006 Class BEN 61000-3-2: 20006 Class DEN 61000-3-3: 1995+A1: 2001+A2: 2005
EN 55024: 1998+A1: 2001+A2: 2003, including\
IEC 61000-4-2: Criterion A
IEC 61000-4-3: Criterion A
IEC 61000-4-4: Criterion A
IEC 61000-4-5: Criterion A
IEC 61000-4-6: Criterion A
IEC 61000-4-11: Criterion A/B/B
Safety cUL
TUVCB
CCC
BSMI

 

Downloads

Specification: PDF